• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
Egyptian Journal of Agricultural Research
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 103 (2025)
Volume Volume 102 (2024)
Volume Volume 101 (2023)
Volume Volume 100 (2022)
Volume Volume 99 (2021)
Volume Volume 98 (2020)
Volume Volume 97 (2019)
Issue Issue 4
Issue Issue 3
Issue Issue 2
Issue Issue 1
Volume Volume 96 (2018)
Volume Volume 95 (2017)
Volume Volume 94 (2016)
Volume Volume 93 (2015)
Volume Volume 92 (2014)
Volume Volume 91 (2013)
Volume Volume 90 (2012)
Volume Volume 89 (2011)
Volume Volume 88 (2010)
Volume Volume 87 (2009)
Volume Volume 86 (2008)
Volume Volume 85 (2007)
Volume Volume 84 (2006)
Volume Volume 83 (2005)
Volume Volume 82 (2004)
Volume Volume 81 (2003)
Volume Volume 80 (2002)
Volume Volume 79 (2001)
Volume Volume 78 (2000)
Volume Volume 77 (1999)
Volume Volume 76 (1998)
Volume Volume 75 (1997)
Volume Volume 74 (1996)
EL-TANTAWY, M., RAMADAN, Y., MERVAT, A., SHAROBEEM, Y. (2019). DEVELOPMENT OF A CYCLONE SEPARATING UNIT ATTACHING TO LOCALTHRESHERS FOR CLEAN ENVIRONMENT. Egyptian Journal of Agricultural Research, 97(4), 747-768. doi: 10.21608/ejar.2019.111105
M. M. EL-TANTAWY; Y. Y. RAMADAN; ATALLAH M. MERVAT; Y. F. SHAROBEEM. "DEVELOPMENT OF A CYCLONE SEPARATING UNIT ATTACHING TO LOCALTHRESHERS FOR CLEAN ENVIRONMENT". Egyptian Journal of Agricultural Research, 97, 4, 2019, 747-768. doi: 10.21608/ejar.2019.111105
EL-TANTAWY, M., RAMADAN, Y., MERVAT, A., SHAROBEEM, Y. (2019). 'DEVELOPMENT OF A CYCLONE SEPARATING UNIT ATTACHING TO LOCALTHRESHERS FOR CLEAN ENVIRONMENT', Egyptian Journal of Agricultural Research, 97(4), pp. 747-768. doi: 10.21608/ejar.2019.111105
EL-TANTAWY, M., RAMADAN, Y., MERVAT, A., SHAROBEEM, Y. DEVELOPMENT OF A CYCLONE SEPARATING UNIT ATTACHING TO LOCALTHRESHERS FOR CLEAN ENVIRONMENT. Egyptian Journal of Agricultural Research, 2019; 97(4): 747-768. doi: 10.21608/ejar.2019.111105

DEVELOPMENT OF A CYCLONE SEPARATING UNIT ATTACHING TO LOCALTHRESHERS FOR CLEAN ENVIRONMENT

Article 16, Volume 97, Issue 4, December 2019, Page 747-768  XML PDF (1.38 MB)
Document Type: Original Article
DOI: 10.21608/ejar.2019.111105
View on SCiNiTO View on SCiNiTO
Authors
M. M. EL-TANTAWY* ; Y. Y. RAMADAN; ATALLAH M. MERVAT; Y. F. SHAROBEEM
Agricultural Engineering Research Institute (AEnRI), ARC, Giza, Egypt
Abstract
This study aims to obtain a clean environment through agricultural activities by developing and evaluating the performance of a cyclone separating unit attached to threshers. Threshing in traditional method depends on emitting chopped wheat straw (Tibn) off the threshers freely in the air and then collected manually by operators causing air pollution and affecting operators' health. The developed cyclone in this study separates dust from the airstream and simultaneously collect the chopped wheat straw instead of operators. According to the obtained data from theoretical calculations (Table 1), the modifications on 2D2D cyclone. The tested performance parameters of the developed cyclone are: four airstream velocities (ASV) of 2.3, 3.6, 4.7 and 5.5 m/s; cyclone inlet dimensions (CID) of (A) 20x30; (B) 25x35; (C) 35x45 cm for width and height, respectively; vortex finder length (VFL) of 50, 60 and 70 cm; cyclone outlets ratios (COR) chopped wheat straw and airstream outlet diameters of 15, 20, 25 and 20, 25, 30 cm for chopped wheat straw and airstream outlet represents ratios of 0.75, 0.80 and 0.83, respectively. The results were summarized in the following points: Separation and collection efficiency value by developed cyclone was 99.8% at inlet velocity of 4.7m/s, vortex finder length of 50 cm, with inlet dimensions of 25x35 cm under cyclone outlet ratio of 0.8. The maximum values of the rising dust was 6.8 mg/m3under the same mentioned conditions while increased by97.5 % with traditional method (without cyclone). Total costs for packing chopped wheat straw under mentioned conditions decreased by 80% in case of using the developed cyclone comparing to the traditional method. It is recommended to manufacture the developed cyclone with vortex finder length of 50 cm, with inlet dimensions of 25x35 cm at outlet ratio of 0.8 to lessen the environmental pollution and conserve laborers' health.
 
Keywords
Environment; cyclone; pressure drop; tangential outlet; collection efficiency
Statistics
Article View: 199
PDF Download: 914